NEW QUESTION # 13
A network architect needs to design a new wireless solution for a small company The architect estimates that about 150 APs will be required to implement a capacity design. Roaming support is required. Also, the design requires meshing to connect some of the APs to the network.
The customer requires that client state synchronization be provided for real-time failover.
Which solution would most cost-effectively meet these requirements?

  • A. FRAPs in a cluster
  • B. Two 7030 mobility controller and campus APs in a cluster
  • C. Two 7205 mobility controller and campus APs in a cluster
  • D. lAPs in a cluster

Answer: A


NEW QUESTION # 14
A company is redesigning their wireless network and will be upgrading all devices to support the latest wireless standards. The company is not near any radar installations. In order to keep wireless NIC power levels as low as possible to reduce interference issues and to take advantage of radar frequency ranges, what IEEE standard should APs support?

  • A. 802.11r
  • B. 802.11 ax
  • C. S02.11h
  • D. S02.11V

Answer: B


NEW QUESTION # 15
A network architect is creating a new wired design for a warehouse building. As a best practice, what length should the architect allow for the service loop in the wiring closets in this environment?

  • A. 3 feet (1 m)
  • B. 15-30 feet (5-10 m)
  • C. 30-60 feet (10-20 m)
  • D. 3-10 feet (1-3 m)

Answer: A


NEW QUESTION # 16
A network architect is designing a new wired and wireless solution for for a company. The company has two buildings on a campus, which each building has three floors. The campus core will be placed in the basement of Building 1. Each wiring closet has eight strands of multi-mode OM3 grade fiber that connect to a wiring closet of the first floor of the building it is contained, referred to as a main distribution frame (MDF). The maximum distance between a floor's wiring closet and the MDF is 100 feet (30 meters). The maximum distance between the two MDFs and the campus core is no more than 150 feet (45 meters). There are eight strands of multi-mode OM3 grade fiber from these two MDF closets to the campus core.
Based on this information, which type of design should be used and what is the maximum speeds supported all uplinks for the existing the multi-mode fiber?

  • A. three-tier and 10 Gbps
  • B. three-tier and 40 Gbps
  • C. two-tier and 10 Gbps
  • D. two-tier and 40 Gbps

Answer: A


NEW QUESTION # 17
A customer has over 100 access layer switches. The customer requires user authentication done via the Aruba Dynamic Segmentation feature. What components are required to implement this solution? (Select two.)

  • A. AirWave server
  • B. Aruba mobility controller
  • C. enterpnse authentication server
  • D. Aruba APs
  • E. Active Directory server

Answer: A,B


NEW QUESTION # 18
Which two challenges do802.1ig barcode scanners present to a WLAN design? (Select two.)

  • A. encountering RF interference by devices
  • B. providing consistent performance on all available channels
  • C. determining the RF channel bandwidth consumed per Barcode scanner
  • D. roaming between APs
  • E. implementing adequate security measures to ensure PCI compliance

Answer: B,E


NEW QUESTION # 19
A customer placed an order for an ArubaOS 5406R switch and plans to rack mount it in a wiring closet. The dimensions of the switch are 17.5 inches wide (44.45 cm), 6.9 inches high (17.5 cm), and 17.75 inches deep (45.1 cm). How many rack units should a customer plan for this switch?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 20
A network architect is designing a new Wi-Fi solution for a customer The customer currently occupies a one-story building on a small campus. In one part of the building there is an auditorium, where the ceiling height and attenuation is different from the rest of the building. What should the network architect create in VisualRF to identify this difference when planning :ne APs?

  • A. Create a Region in the Floorplan View
  • B. Define the appropriate properties in the Building View
  • C. Define the appropriate properties in the Network View
  • D. Spit the Building View into two Floorplan Views

Answer: B


NEW QUESTION # 21
NewRocket requires a wireless capacity design 30 Aruba 510 APs will be connected to each wiring closet using SmartRate connections. Wireless coverage needs to be provided even if a POE+ switch loses power Because of security concerns, wired video cameras were recently installed throughout the facility. There are 12 of these per floor. 6 per wiring closet. The cameras are 802.11n WiFi capable and have power injectors from which to draw power.
Based on the POE+ needs of the mentioned devices, which solution would meet the POE+ requirements while still providing a redundant and cost-effective Wi-Fi solution for the devices that require POE+ for Building 1, Floor 2?

  • A. Two 2930M 24-port POE+ switches
  • B. One 2930M 48-port POE+ switch
  • C. Two 2930F 24-port POE+ switches
  • D. One 3810M 40G 8 HPE Smart Rate switch

Answer: B


NEW QUESTION # 22
A high-end theater venue will be implementing an Aruba wireless solution using ceiling- and wall-mounted APs. The venue wants to ensure the the APs blend into the ceiling and wall environments. What solution should the customer use to ensure that wireless coverage is not hampered?

  • A. Paint the APs to match the ceilings or walls
  • B. Order Aruba AP covers for the APs
  • C. Place the APs above the ceiling and behind the walls
  • D. Place a strip of tape over the LEDs

Answer: C


NEW QUESTION # 23
A company has two buildings on a campus that are approximately 700 feet (214 meters) apart with a clear line of site. No fiber exists between the buildings; however, there is a need for connecting the networks in the buildings together. The connection between the two buildings will need to support peak rates over 1 Gbps.
Which solution should the company choose that will meet their requirements as well as being cost-effective?

  • A. Two outdoor AP 387s
  • B. Two outdoor AP 367s
  • C. Multi-mode fiber between campus switches
  • D. Two outdoor AP 510s

Answer: B


NEW QUESTION # 24
A network architect is designing a Wi-Fi solution for a customer using Aruba Central's VisualRF tool When creating a Campus view, how would the network architect pull in a map that displayed the campus location in a city?

  • A. Create a screen capture from any web-based map site and import the picture file
  • B. Import the longitude and latitude information from any web-based map site
  • C. Use VisualRF's built-in map tool and define the appropriate longitude and latitude information
  • D. Import the longitude and latitude information from Google Maps

Answer: B


NEW QUESTION # 25
A network architect is replacing an old wireless implementation based on 802.11 a with a new wireless solution. The company has a lot of money invested in legacy wireless barcode scanners and will not be replacing them. However, the bandwidth that the company expects each AP to have less than 700 Mbps in bandwidth, and this is not expected to change in the future.
Which wireless solution would best meet this company's needs and be the most cost-effective?

  • A. 802.11g
  • B. 802.11n
  • C. 802.11ac
  • D. 802.11ax

Answer: D


NEW QUESTION # 26
A network architect imports a floorplan defined in a PNG file format What is the function of the measurement tool in Aruba's VisualRF?

  • A. Define the appropriate dimensions of a Floorplan View
  • B. Define the appropriate dimensions of a Floorplan and Building View
  • C. Define the appropriate dimensions of each room in a Floorplan View
  • D. Define the appropriate dimensions of each object in a Floorplan View

Answer: D


NEW QUESTION # 27
A network architect has developed a design for a new Aruba Wi-Fi network that will include a hardware Mobility Master (MM) running the ArubaOS 8 4 operating system that will manage:
* Two clustered 7205 controllers with 300 campus APs
* Two clustered VMC-50 controllers with 75 remote APs
The architect plans on creating user roles, firewall policies, and wireless IPS policies on the controllers as well as implementing AirMatch. What would meet the license requirements for this scenario?

  • A. LIC-MC-VA-50 (X2), LIC-AP (375), PEF (X375), RFP (X375)
  • B. LIC-MM-VA-500. LIC-MC-VA-50 (X2), LIC-AP <x375). PEF (x375). RFP (x375)
  • C. LIC-MC-VA-50 (x1), LIC-AP (300), PEF (X300). RFP (x300)
  • D. LIC-MM-VA-50, LIC-MC-VA-50 (X1), LIC-AP (X300), PEF <x300). RFP (x300)

Answer: D


NEW QUESTION # 28
A network architect wants to estimate the number of Aruba APs that will be needed Tor a new wireless design and determine the wireless coverage using VisualRF. The company requires a high-density design. The building has 200.000 square feet. How many APs should the network architect add to VisualRF in order to perform the coverage analysis?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 29
A company has two buildings on a campus, where each building has three floors, which two wiring closets per floor Assume that there will be 24 APs connected via POE+ to each wiring closet, along with 128 wired user connections. Which backplane stacking solution will provide the necessary Ethernet port capacity for all devices on Building 1 Floor 2 and is fully meshed?

  • A. Two 381 OM 24-port POE+ switches and three 381OM 48-port switches per wiring closet
  • B. Two 2930F 24-port POE+ switches and three 2930F 48-port switches per wiring closet
  • C. One 2930M 24-port POE+ switch and two 2930M 48-port switches per wiring closet
  • D. One 381 OM 24-port POE+ switches and two 2930M 48-port switches per wiring closet

Answer: C


NEW QUESTION # 30
A company needs to replace an existing legacy wireless and wired solution with one that supports features like 802 11 ax for APs and logical switching for switches. The company is located on a single floor with two wiring closets. Assume that there will be 10 APs connected via POE+ to each wiring closet, along with 36 wired user connections All switches on a floor should be configured in a single stack. The distance between wiring closets is 100 feet (31 meters).
Which switching solution will minimally provide 10 Gbps uplinks at the most cost-effective price, while still meeting the company's requirements?

  • A. 3810M switches
  • B. 5406R switches
  • C. 2930M switches
  • D. 2930F switches

Answer: C


NEW QUESTION # 31
Which type of Aruba AP uses its radio as its back-haul connection?

  • A. Remote AP (RAP)
  • B. Mesh Point
  • C. Air Monitor (AM)
  • D. Mesh Porta

Answer: D


NEW QUESTION # 32
......

Free HP HPE6-A66 Exam 2023 Practice Materials Collection: https://www.dumps4pdf.com/HPE6-A66-valid-braindumps.html