NS0-593 Training & Certification Get Latest NetApp NCSE Updated on Aug 15, 2022
Certification Training for NS0-593 Exam Dumps Test Engine
NetApp NS0-593 Exam Certification Details:
| Exam Registration | PEARSON VUE |
| Sample Questions | NetApp NS0-593 Sample Questions |
| Duration | 120 minutes |
| Number of Questions | 60 |
| Exam Name | Support Engineer ONTAP Specialist |
| Passing Score | 62% |
| Exam Code | NS0-593 NCSE ONTAP |
| Exam Price | $150 USD |
NEW QUESTION 25
A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G
Ethernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1.
You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.
What is the cause of the customer's problem?
- A. The cable is plugged in upside down.
- B. The port has an incorrect SFP inserted.
- C. The ports are configured for 4x10Gbit instead of 40Gbit.
- D. The incorrect cable is used.
Answer: C
NEW QUESTION 26
You have connection Issues from a Linux host to an AFF A400 FC LUN. You are asked by support to run the
NetApp sanlun command to provide troubleshooting information.
Which NetApp software package must be installed on the host?
- A. Virtual Storage Console
- B. Host Utilities package
- C. SnapDrive for UNIX
- D. Inventory Collect Tool
Answer: B
NEW QUESTION 27
Your customer complains that u host will constantly report losing a connection to the iSCSl target and then
report that the session was reestablished.
As shown in the exhibit, what is a cause of this flapping?
- A. A host with an IP address of 172.20.10.80 and a secondIP address of 10.10.20.60 is accessing different LUNs.
- B. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 have the
same IQN. - C. A host with an IP address of 172.20.10.80 and a secondhost with an IP address of 10.10.20.60 are in
different initiator groups. - D. A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 are
accessing the same LUN.
Answer: D
NEW QUESTION 28
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is
accessed indirectly. The system node run -node -command netstat command shows retransmits and packet
drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster
interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP
9.8 software.
In this scenario, what is causing this problem?
- A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
- B. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
- C. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
- D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.
Answer: A
NEW QUESTION 29
After a normal power down of both nodes forbuilding maintenance, Node01 of a 2-node cluster cannot be
powered back up; however, all disk shelves are powered.
Which action should be performed to bring the cluster online and allow Node02 to serve data?
- A. Reinitialize the cluster with option 4a from the boot menu.
- B. Recreate the cluster with the system configuration recovery cluster recreate -from node command.
- C. Reboot the node With the system node reboot -node Node02 -bypass-optimization true command.
- D. Perform a takeover with the storage failover takeover -ofnode Node01 -option forcecommand.
Answer: B
NEW QUESTION 30
You recently discovered the error message shown below in your ONTAP logs.
What should be your first action to correct this Issue?
- A. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.
- B. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol
volume. - C. Use the storage takeover command on the storage controller that contains my_data_vol.
- D. Determine the root cause behind the inconsistency before attempting any recovery procedure.
Answer: B
NEW QUESTION 31
You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They
provided you packet traces from the controller and client. Analysis of these traces shows an average service
response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in
the same time period.
In this situation, what would be your next step?
- A. A sync core should be triggered.
- B. The cluster interconnects should be investigated.
- C. The cluster is responding slowly and requires further investigation using performance archives.
- D. The client that reports high latency should be investigated.
Answer: D
NEW QUESTION 32
You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster running
NetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event log
has the message shown below.
ISCSI: network interface identifier disabled for use; incoming connection discarded
In this scenario, what is the cause of this connection issue?
- A. The iSCSI service is not enabled on the interface.
- B. The WWPN was not added to the initiator group.
- C. CHAP isnot configured correctly for the specified initiator.
- D. iSNS is not enabled on the storage virtual machine.
Answer: B
NEW QUESTION 33
Which two automation methods does NetApp ONTAP Select support? (Choose two.)
- A. PHP
- B. Docker
- C. Anslble
- D. REST
Answer: C,D
NEW QUESTION 34
Which two throughput elements are controlled by host applications? (Choose two.)
- A. Jitter
- B. operation size
- C. latency
- D. concurrency
Answer: A,C
NEW QUESTION 35
Your customer calls you because one application is not able to access a NetApp ONTAP S3 bucket. While
reviewing the EMS log on the cluster, you see the following message:
The same credentials work in another application.
In this scenario, what would cause this problem?
- A. The application is using v4 signatures.
- B. The application is trying to access using the HTTP protocol.
- C. The application is using v2 signatures.
- D. The application is trying to log in as an anonymous user.
Answer: D
NEW QUESTION 36 
Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?
- A. Enter the storage failover giveback command on Site B.
- B. Enter the metrocluster switchback command on Site A.
- C. Enter the storage failover giveback command on Site A.
- D. Enter the metroclustor switchback command on Site B.
Answer: B
NEW QUESTION 37
Your customer complains about missing volume snapshot copies on a SnapMlrror destination. While
investigating this case, you notice an executed SnapMirror resync operation in the event logs of the system.
In this scenario, what Is the cause of this problem?
- A. Newer Snapshot copies than the common snapshot that was chosen for resync were removed
automatically at the destination. - B. Snapshot copies were manually removed from the destination after the resync.
- C. The autodelete option removed Snapshot copies before the resync.
- D. NetApp ON TAP System Manager removed these snapshot copies due to a snapshot schedule.
Answer: B
NEW QUESTION 38
You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF
A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from
each VM on the shared FC LUN-backed datastores for troubleshooting purposes.
In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?
- A. Network I/O Control (NIOC)
- B. vSphere Cluster Services (vCLS)
- C. Virtual machine ID (VMID)
- D. Storage I/O Control (SIOC)
Answer: B
NEW QUESTION 39
When an administrator tries to create a share for an existing volume named voll, the process fails with an error.
Referring to the exhibit, what Is the reason for the error?
- A. The volume has not beenmounted.
- B. The CIFS service is not in workgroup mode.
- C. The volume must have a type of DP.
- D. The CIFS service is not authenticating properly with the domain controller.
Answer: A
NEW QUESTION 40
Your customer Informs you about SnapMlrror problems after upgrading NetApp ONTAP software to a newer
version. After investigating the event logs and the SnapMirror history, you see information about delayed
updates of the SnapMirror relationships.
How would your customer prevent such problems in the future?
- A. Verify that the cabling of the hardware port that Is responsible for SnapMirror transfers Is correct.
- B. Modify the schedules of the SnapMirror relationships after upgrading the ONTAP software.
- C. Delete the SnapMirror relationships and create them new after upgrading the ONTAP software.
- D. Quiesce the SnapMirror relationships before upgrading the ONTAP software.
Answer: A
NEW QUESTION 41
......
Network Appliance NS0-593 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
Step by Step Guide to Prepare for NS0-593 Exam: https://www.dumps4pdf.com/NS0-593-valid-braindumps.html
NetApp NCSE NS0-593 Real Exam Questions and Answers FREE Updated: https://drive.google.com/open?id=1NSrZ0JmMEU_95P8mS93nJlOfsRFHTnRW