220-1101 Practice Test Give You First Time Success with 100% Money Back Guarantee!
All Obstacles During 220-1101 Exam Preparation with 220-1101 Real Test Questions
CompTIA A+ Certification Exam: Core 1, also known as the CompTIA 220-1101 exam, is a certification exam that measures the candidate's knowledge and skills in the field of IT support. 220-1101 exam is one of two required to obtain the CompTIA A+ certification. CompTIA A+ Certification Exam: Core 1 certification is recognized globally and is often a requirement for entry-level IT support positions.
NEW QUESTION # 196
A developer is requesting permission to utilize client-side visualization. The developer would like to write code in a setting isolated from other infrastructure to avoid negative impacts of experimental code. Which of the following provides the BEST solution for the developer?
- A. Test case development
- B. Sandbox environment
- C. Software compatibility
- D. Cross-platform functionality
Answer: B
Explanation:
A sandbox environment is an isolated testing environment where code can be written and tested without impacting other infrastructure. This provides a safe and controlled environment for experimentation and development. Reference: CompTIA A+ Certification Exam Core 2 Exam Objectives - 5.5 Compare and contrast common workstation security best practices
NEW QUESTION # 197
After a technician updated the wireless APs to 5GHz, users report they have degraded Wi-Fi performance. The technician tests for interference but finds none. Which of the following should the technician do next?
- A. Upgrade the wireless drivers on the users' devices.
- B. Add more access points for better coverage.
- C. Select a different channel.
- D. Switch the Wi-Fi back to the 2.4GHz frequency.
Answer: B
Explanation:
A: Select a different channel: Useful for interference resolution but not coverage improvement. Incorrect.
B: Switch the Wi-Fi back to 2.4GHz frequency: This downgrades the network speed, which isn't a preferred solution. Incorrect.
C: Upgrade the wireless drivers on the users' devices: Unlikely to resolve coverage issues. Incorrect.
D: Add more access points for better coverage: Improves coverage in areas where 5GHz struggles. Correct.
Explanation:
Step by Step Detailed Comprehensive Explanation with All CompTIA Reference:
Analysis of the Problem:
Switching to the 5GHz frequency improves speed but decreases range and penetration through walls compared to 2.4GHz.
Users experience degraded performance likely due to poor coverage at the 5GHz range.
Option Evaluation:
NEW QUESTION # 198
Which of the following components houses the MX record?
- A. DHCP
- B. SMTP
- C. VLAN
- D. DNS
Answer: D
Explanation:
Explanation
The MX record is housed in the DNS (Domain Name System) which is responsible for translating domain names into IP addresses and vice versa. The MX record specifies the mail server responsible for accepting email messages on behalf of a domain name and is a resource record in the DNS123.
NEW QUESTION # 199
A customer calls the help desk to report a problem connecting to a shared drive on a server. The technician determines that the user's server credentials have expired and reactivates them. Which of the following should the technician do next?
- A. Escalate the issue.
- B. Verify system functionality.
- C. Perform backups of all critical data.
- D. Document the findings.
Answer: B
Explanation:
After resolving the immediate issue (reactivating server credentials), verifying system functionality ensures the solution works as intended and the user can now access the shared drive. This step is a part of the CompTIA troubleshooting methodology:
* Identify the problem.
* Establish a theory of probable cause.
* Test the theory to determine the cause.
* Establish a plan of action.
* Implement the solution.
* Verify full system functionality.
* Document findings, actions, and outcomes.
* Why Not B (Document the findings): Documentation comes after verifying the system works.
* Why Not A (Escalate the issue): Escalation is unnecessary since the problem was resolved.
* Why Not C (Perform backups): Performing backups is unrelated to verifying credential functionality.
CompTIA A+ Exam Reference: Core 2 (220-1102), Section 3.1, troubleshooting methodology.
NEW QUESTION # 200
Which of the following utilizes TCP ports 20/21 and transfers data in cleartext?
- A. FTP
- B. Telnet
- C. SNMP
- D. SSH
Answer: A
Explanation:
Explanation
FTP (File Transfer Protocol) uses TCP ports 20/21 and transfers data in cleartext, which means the data is not encrypted and can be read by anyone who intercepts it. This makes FTP insecure for transferring sensitive information. SSH (Secure Shell), on the other hand, uses port 22 and encrypts data, making it more secure.
SNMP (Simple Network Management Protocol) uses ports 161/162 and is used to monitor network devices.
Telnet uses port 23 and transfers data in cleartext, making it insecure. References: CompTIA A+ Certification Exam: Core 1 - Page 199
NEW QUESTION # 201
Which of the following cables provides the best performance with the least EMI?
- A. Cat 7
- B. Cat 6
- C. Coaxial
- D. Cat 5
Answer: A
NEW QUESTION # 202
Every time a user sends a print job, the user must walk over to the printer and press OK before the job will print. The same issue is occurring for multiple users. Which of the following is the MOST likely cause of the issue?
- A. The wrong network printer queue is being used.
- B. The default paper type has been changed.
- C. The print server has outdated print drivers.
- D. The network printer is on the wrong VLAN.
Answer: B
Explanation:
The message prompting to press "OK" indicates that the printer is waiting for a user input. This suggests that there is some issue with the printer settings, and the most probable cause is that the default paper type has been changed, and the printer needs the user to confirm the paper type before proceeding with the print job. This is a common issue that can occur when the default paper type is not set correctly or has been changed without the user's knowledge.
NEW QUESTION # 203
A technician is setting up a video-editing workstation and the operating system is already installed on an internal M.2 drive.
The new workstation must meet the following requirements:
. Be able to edit files at the fastest speed
. Allow for disk failure without any downtime
Have 2TB of usable space
. Ensure the most robust fault tolerance
INSTRUCTIONS
Use the drop-down menus to select the appropriate RAID level, drive types, and drive sizes based on the requirements above. For each drive type that is selected, a corresponding drive size must also be selected.

Answer:
Explanation:
Explanation:
Based on the requirements, the best option for the video-editing workstation is to use RAID 10 with four SATA SSDs of 1TB each. This configuration will meet the following requirements:
* Be able to edit files at the fastest speed: RAID 10 combines the advantages of RAID 0 and RAID 1, which are striping and mirroring, respectively. Striping can increase the data transfer rate by using multiple disks in parallel, while mirroring can provide redundancy and reliability by duplicating the data on another set of disks. SATA SSDs are also faster than HDDs or SSHDs, as they use flash memory instead of spinning disks, and they can offer lower latency, higher IOPS, and less noise and heat.
* Allow for disk failure without any downtime: RAID 10 can withstand up to two disk failures, as long as they are not in the same mirrored pair. If one disk fails, the data can be read from or written to the other disk in the same pair, without affecting the performance or availability of the array. The failed disk can be replaced and rebuilt without interrupting the operation of the workstation.
* Have 2TB of usable space: RAID 10 uses half of the total disk capacity for mirroring, so the usable space is equal to the size of two disks. By using four SATA SSDs of 1TB each, the total disk capacity is
4TB, and the usable space is 2TB, which meets the requirement.
* Ensure the most robust fault tolerance: RAID 10 offers the highest level of fault tolerance among the standard RAID levels, as it can survive multiple disk failures and provide fast recovery. RAID 10 also has a low overhead, as it does not use parity or checksums, which can slow down the write performance or increase the complexity of the array.
Therefore, the technician should select the following options from the drop-down menus:
* RAID level: RAID 10
* Drive type 1: SATA SSD
* Drive size 1: 1TB
* Drive type 2: SATA SSD
* Drive size 2: 1TB
* Drive type 3: SATA SSD
* Drive size 3: 1TB
* Drive type 4: SATA SSD
* Drive size 4: 1TB
* Drive type 5: SATA SSD
* Drive size 5: 1TB
NEW QUESTION # 204
A technician is troubleshooting poor printing quality on an inkjet printer. The pages have white lines running through the text and graphics. Which of the following is the most likely cause?
- A. Clogged printhead
- B. Faulty ink cartridges
- C. Worn out rollers
- D. Poor quality paper
Answer: A
Explanation:
White lines running through text and graphics in printouts from an inkjet printer are commonly caused by clogged printheads. When the printhead nozzles are clogged, they cannot deliver ink properly to the paper, resulting in white lines where ink should have been deposited. Worn-out rollers, faulty ink cartridges, and poor-quality paper can cause other printing issues but are less likely to cause white lines in the printed output.
Reference:
CompTIA A+ Core 1 Exam Objectives Section 3.7: Given a scenario, install and replace printer consumables.
NEW QUESTION # 205
A server administrator is building a new application server. Which of the following, RAID levels provides MAXIMUM performance and redundancy?
- A. RAID 10
- B. RAID 1
- C. RAID 0
- D. RAID 5
Answer: A
Explanation:
Explanation
RAID 10 is a combination of RAID 1 and RAID 0, which provides both performance and redundancy. RAID
1 mirrors data across two or more disks, while RAID 0 stripes data across two or more disks. RAID 10 combines these two methods to create a mirrored stripe set, which can tolerate multiple disk failures as long as they are not in the same mirror. RAID 10 requires at least four disks and offers better performance than RAID
5, which uses parity to provide redundancy. References:
https://www.comptia.org/blog/what-is-raid-0-1-5-6-10
NEW QUESTION # 206
A computer that contains critical data has not been backed up and will not boot past a S. M. A. R. T, error that indicates imminent hard disk failure. Which of the following actions should the technician take FIRST?
- A. Attempt to boot the operating system in safe mode
- B. Run diagnostics on the faulty hard drive using a boot disk
- C. immediately replace the hard drive generating the SMART error
- D. Turn off S. M. A. R. T, monitoring in the computer's BIOS settings
Answer: B
Explanation:
Explanation
The technician should run diagnostics on the faulty hard drive using a boot disk first when a computer that contains critical data has not been backed up and will not boot past a S.M.A.R.T. error that indicates imminent hard disk failure. References: CompTIA A+ Certification Exam Guide, Exam 220-1001, Page 376
NEW QUESTION # 207
A customer built a computer for gaming, sourcing individual components and then assembling the system. The OS starts up, but within a few minutes the machine locks up. The customer brought the computer to a technician to diagnose the issue.
Answer:
Explanation:
Explanation
correct answer is "Overclocking" and "Reduce CPU Clock speed" CPU is at 4.5 Ghz when normal is 3.2 Ghz.
Overclocking too much can cause freezes, and this is a gaming computer so the user probably took it too far.
http://blog.logicalincrements.com/2018/12/4-troubleshooting-tips-overclocking-pc/
NEW QUESTION # 208
A natural disaster occurred, and the storage system for the development team is unrecoverable. The technician is preparing replacement storage arrays that include a hypervisor with the capacity to support several virtual machines. Two separate bays are available, and both should be utilized.
Requirements for the primary array include the following:
* No need to be scalable
* Very fast on reads
* Fault tolerance of one drive
* Ability to function with only one drive
* Easily recoverable data
* High redundancy
* Minimum number of drives
Requirements for the secondary array include the following:
* Fault tolerance of one drive
* Total space of 600G3
* Best write performance
* Minimum number of drives
Instructions:
Drag and Drop the appropriate Hard Drives. Then Open each array to complete the configuration.
Answer:
Explanation:
Explanation:
Primary Array:
* Drag and drop two 120 GB SSD hard drives to the primary array bay.
* Open the primary array and select RAID 1 as the RAID level. RAID 1 provides fault tolerance of one drive, ability to function with only one drive, easily recoverable data, high redundancy, and very fast on reads. It also does not need to be scalable and uses the minimum number of drives (two) for RAID 1.
* Confirm the configuration and close the primary array.
Secondary Array:
* Drag and drop two 300 GB SSD hard drives to the secondary array bay.
* Open the secondary array and select RAID 0 as the RAID level. RAID 0 provides the best write performance and uses the minimum number of drives (two) for RAID 0. It also provides a total space of
600 GB (300 GB x 2), which meets the requirement.
* Confirm the configuration and close the secondary array.
You have completed the configuration of the storage arrays.
NEW QUESTION # 209
Laura, a customer, has instructed you to configure her home office wireless access point.
She plans to use the wireless network for finances and has requested that the network be setup with the highest encryption possible.
Additionally, Laura knows that her neighbors have wireless networks and wants to ensure that her network is not being interfered with by the other networks.
She requests that the default settings be changed to the following.
Wireless Name: HomeWiFi
Shared Key: CompTIA
Router Password: Secure$1
Finally, Laura wants to ensure that only her laptop and Smartphone can connect to the network.
Laptop: IP Address 192.168.1.100
Hardware Address: 00:0A:BF:03:C4:54
Smartphone: IP Address 192.168.1.101
Hardware Address: 09:2C:D0:22:3F:11
INSTRUCTIONS
Configure Laura's wireless network using the network adapter window.
If at any time you would like to bring back the initial state of the situation, please click the Reset All button.



Answer:
Explanation:
solution as


NEW QUESTION # 210
A technician is troubleshooting a laptop that shuts down intermittently When the laptop is repositioned, the technician notices a noise coming from inside of it. The technician removes the bottom cover Which of the following should the technician do next?
- A. Turn on the laptop and move it again to replicate the issue.
- B. Remove the internal battery and look for loose parts.
- C. Reseat the memory modules and the SSD.
- D. Inspect the connections for a damaged cable.
Answer: A
Explanation:
The correct answer is A. Turn on the laptop and move it again to replicate the issue.
One of the basic troubleshooting techniques is to reproduce the problem and observe the symptoms. This can help to identify the cause and the solution of the issue. By turning on the laptop and moving it again, the technician can verify if the noise is related to the laptop's movement, and if it affects the laptop's performance or stability. The noise could indicate a loose or damaged component, such as a fan, a hard drive, or a cable, that needs to be fixed or replaced.
The other options are not the best next steps, because they do not confirm the source of the problem, and they may cause more damage or complications. Reseating the memory modules and the SSD (option B) may be helpful if the laptop has booting or performance issues, but it is unlikely to solve the noise problem. Removing the internal battery and looking for loose parts (option C) may be risky if the technician does not follow proper safety precautions, such as disconnecting the power cord and wearing an anti-static wrist strap. Inspecting the connections for a damaged cable (option D) may be part of the troubleshooting process, but it should be done after replicating the issue and narrowing down the possible causes.
For more information about laptop troubleshooting steps, you can refer to the following web search results: Computer Basics: Basic Troubleshooting Techniques, Use a fix-it tool with Windows 10, 6 Ways to Troubleshoot a Computer.
NEW QUESTION # 211
A technician configured a new SOHO router for a small business. The ISP gave the technician an IP address on the router's WAN port. Which of the following addresses did the technician most likely configure on the router?
- A. 10.1.50.30
- B. 172.22.40.6
- C. 169.254.168.10
- D. 19.45.7.28
Answer: D
Explanation:
Explanation
This is an example of a public IP address that can be assigned by an ISP to a router's WAN (Wide Area Network) port. A public IP address is a globally unique and routable address that allows a device to communicate with other devices on the internet. A private IP address, such as 10.1.50.30 or 172.22.40.6, is a non-routable address that is used within a local network and cannot be directly accessed from the internet. A link-local IP address, such as 169.254.168.10, is a self-assigned address that is used when a device cannot obtain a valid IP address from a DHCP server.
NEW QUESTION # 212
A technician is upgrading a user's laptop from an HDD to an SSD. The user's laptop only has a single bay for a hard drive. Which of the following characteristics of the SSD is the most important in this scenario?
- A. Partition type
- B. Form factor
- C. Storage size
- D. Transfer speed
Answer: B
Explanation:
When upgrading a laptop's storage from an HDD to an SSD, especially in laptops with only a single bay for a hard drive, the most critical characteristic to consider is the form factor. The form factor must match the physical dimensions and interface of the original HDD to ensure that the SSD can fit into the bay and connect properly. Storage size (B) is important for capacity reasons, transfer speed (D) affects performance, and partition type (A) is a software configuration aspect, but the form factor (C) is crucial for the physical compatibility of the SSD with the laptop.
References:
* CompTIA A+ Core 1 Exam Objectives Section 3.3: Given a scenario, select and install storage devices.
NEW QUESTION # 213
A user wants a second monitor installed on a laptop. The VGA/DVI or HDMI cables have already been connected. Which of the following should the technician do to configure the laptop to show both screens?
- A. Plug in the monitor to the USB port.
- B. Power cycle the laptop.
- C. Power cycle the monitor.
- D. Adjust the monitor display settings.
Answer: D
Explanation:
Explanation
To configure the laptop to show both screens, the technician should adjust the monitor display settings. On Windows 10 or 11, the technician can select the Start menu, then open Settings, then select Display. The PC should automatically detect the monitors and show the desktop. If the monitors are not detected, the technician can select Multiple displays, then Detect. The technician can then use the dropdown list next to the image of the desktop to choose how the screen will project across the displays
NEW QUESTION # 214
Which of the following cloud models provides hardware environment equivalent components to develop a solution?
- A. SaaS
- B. DBaaS
- C. PaaS
- D. laaS
Answer: D
Explanation:
Infrastructure as a Service (IaaS) provides virtualized computing resources over the internet, including virtualized hardware, storage, and networking components. It offers the infrastructure on which clients can install their operating systems and applications, providing an equivalent to physical hardware environments.
This allows developers and businesses to develop and run their solutions without managing physical servers.
SaaS delivers software applications over the internet, PaaS provides a platform allowing customers to develop, run, and manage applications, and DBaaS offers database services in the cloud.
References:
* CompTIA A+ Core 1 Exam Objectives Section 4.1: Summarize cloud computing concepts.
NEW QUESTION # 215
......
CompTIA 220-1101, also known as the CompTIA A+ Certification Exam: Core 1, is an entry-level certification exam designed to test the fundamental knowledge and skills required of IT professionals. 220-1101 exam covers a broad range of topics related to computer hardware, software, networking, and security, making it an essential credential for anyone looking to pursue a career in IT support or administration.
Fully Updated Free Actual CompTIA 220-1101 Exam Questions: https://www.dumps4pdf.com/220-1101-valid-braindumps.html
Free 220-1101 Questions for CompTIA 220-1101 Exam [Mar-2026]: https://drive.google.com/open?id=10QRSdtR6QrqMdvMS7bsvol8RXMvZGwfO